4. Troubleshooting

Communication errors

  • Verify the values of WG_CAM_IP and WG_CAM_PORT in Program → Before Start → User Config.
  • Ensure the robot server on the Machine Vision Device is active: navigate to the device website → Jobs → Processing Instance → Robot Server.
  • Check network connectivity and firewall rules between the robot controller and the Machine Vision Device.
  • If the socket cannot be opened at all, wenglor_helpers.connect_with_vision_device shows "No connection to vision device. Program stopped." and halts — this points to a network- or address-level issue rather than a protocol error.

Insufficient calibration accuracy

You can improve calibration accuracy by using more than five calibration poses. Add additional calibration movements — each followed by a call to wenglor_api.add_calibration_pose — in Program → wenglor_api → run_calibration, after the existing WG_CALIB_POSE_5 step and before calibration:calculate[...] is sent.

Note

See the wenglor Robot Server overview in the wenglor robot vision manual for calibration-plate selection, pose-variation recommendations, and how to interpret the reprojection error returned by calibration:calculate.

Error codes returned by the device

If the robot server returns a negative error code (-5001-5010), wenglor_helpers.check_camera_reply detects it (reply starts with -) and wenglor_helpers.set_return_error maps it to a readable popup message before the program halts. For the meaning of each code, see the Generic Robot Vision Interface → Error codes in the wenglor robot vision manual.

Program exits unexpectedly

Cause Detail Message shown
g_detection_pose not set The example routines compare it against WIG_EMPTY_POSE and halt if it still matches.
Calibration poses not set WG_CALIB_POSE_1WG_CALIB_POSE_5 must not equal WIG_EMPTY_POSE; wenglor_helpers.are_calibration_poses_set checks each of them before run_calibration proceeds.
No reply from the camera, or an empty socket read wenglor_helpers.check_camera_reply detects the missing reply. Check the device state via state[WG_USE_CASE];. "No reply from camera. Exiting program."
Unknown use case WG_USE_CASE must be exactly camera_on_robot or camera_not_on_robot; any other value halts run_calibration. "Unknown use case. Program was aborted."

Documentation revision note

Earlier revisions used lowercase variable names; see User Configuration for the current names.